| SOMY SHIPS BOILERS & CALORIFIERS Technical Information | |||
| Somy Compact Boilers | Model |
C0814 |
C2028 |
C2836 |
C3650 |
|
![]() |
Kw
Output |
10-16 |
20-25 |
28-36 |
36-50 |
|
Dim. A(mm) |
368 |
470 |
470 |
530 |
||
Dim. B(mm) |
635 |
665 |
728 |
768 |
||
Dim. C(mm) |
490 |
570 |
570 |
665 |
||
Dim. D(mm) |
81 OD |
130 |
130 |
150 |
||
Dim. E(mm) |
340 |
340 |
340 |
340 |
||
Dim. F(mm) |
420 |
441 |
504 |
543 |
||
Dim. L(mm) |
700 |
780 |
780 |
878 |
||
| The Compact Boiler Range is
ideal for applications where there is a separate hot water calorifier
or for installations where only heating is required.
|
||||||
| Somy Delta Boilers | Model
|
F25 |
F35 |
F45 |
||
![]() |
Kw Output |
22-29 |
29-40 |
38-54 |
||
Dim. A(mm) |
1497 |
1697 |
1497 |
|||
Dim. B(mm) |
1260 |
1460 |
1260 |
|||
Dim. C(mm) |
130 |
130 |
150 |
|||
Hot Water Output
@ 45 deg.(C) |
799L |
1027L |
1112L |
|||
Max Working Pressure
of Hot Water |
10BAR |
10BAR |
10BAR |
|||
| The Delta boiler again has
an integral stainless steel calorifier. The flue gasses pass through the
calorifier transferring residual heat to the domestic hot water. This
makes the Delta an extremely efficient boiler for vessels with limited
240V electrical capacity. The top flue connection gives the unit a very
small foot print. |
||||||
| Somy Calorifiers - Details | ||||||
| HL Calorifiers for horizontal or vertical mounting. (No immersion option) | ||||||
| Model | HL100 |
HL130 |
HL160 |
HL210 |
HL240 |
|
| Total capacity | 105 |
130 |
161 |
203 |
242 |
|
| Heating fluid cap. (L) | 30 |
31 |
35 |
39 |
42 |
|
| Hot water cap. (L) | 75 |
99 |
126 |
164 |
200 |
|
| Flow rate (L per Hr.) | 2100 |
2600 |
3500 |
4200 |
5500 |
|
| Heating fluid connections (Ø) | 5/4" |
5/4" |
5/4" |
5/4" |
5/4" |
|
| Safety valve connections (Ø) | 3/4" |
3/4" |
3/4" |
3/4" |
3/4" |
|
| Hot water connections (Ø) | 3/4" |
3/4" |
3/4" |
3/4" |
3/4" |
|
| Heating Surface (sq. m) | 1,03 |
1,26 |
1,54 |
1,94 |
2,29 |
|
| Weight empty (Kg) | 40 |
47 |
55 |
65 |
75 |
|
| Dimensions A | 818 |
978 |
1178 |
1450 |
1697 |
|
| Dimensions B | 600 |
760 |
960 |
1232 |
1479 |
|
| Max operating pressure (bar): | ||||||
| Heating fluid | 3 |
3 |
3 |
3 |
3 |
|
| Hot water | 10 |
10 |
10 |
10 |
10 |
|
![]() |
![]() |
|||||
| Smartline Calorifiers for vertical mounting only (With Immersion) | ||||||
| Model | SL130 |
SL160 |
SL210 |
SL240 |
SL320 |
|
| Total capacity | 130 |
161 |
203 |
242 |
318 |
|
| Heating fluid cap. (L) | 55 |
62 |
77 |
78 |
55 |
|
| Hot water cap. (L) | 75 |
99 |
126 |
164 |
263 |
|
| Flow rate (L per Hr.) | 2100 |
2600 |
3500 |
4200 |
6200 |
|
| Heating fluid connections (Ø) | 1" |
1" |
1" |
1" |
6/4" |
|
| Hot water connections (Ø) | 1" |
1" |
1" |
1" |
6/4" |
|
| Heating Surface (sq. m) | 1,03 |
1,26 |
1,54 |
1,94 |
2,65 |
|
| Weight empty (Kg) | 55 |
65 |
75 |
87 |
140 |
|
| Dimensions A | 960 |
1160 |
1435 |
1680 |
1550 |
|
| Dimensions B | 555 |
555 |
555 |
555 |
660 |
|
| Max operating pressure (bar): | ||||||
| Heating fluid | 3 |
3 |
3 |
3 |
3 |
|
| Hot water | 10 |
10 |
10 |
10 |
10 |
|
| Immersion heater (Kw) | 2.2 |
2.2 |
2.2 |
2.2 |
2.2 |
|